Product Description:
720Watts / 1200VA UPS

BR1200GI Features

LCD graphics display 
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Battery replacement without tools 
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Telephone dataline surge protection 
Provides protection of connected equipment from power surges traveling on telephone lines.
Resettable circuit breaker 
Easy recovery from overloads; no need to replace a fuse.
Boost and Trim Automatic Voltage Regulation (AVR) 
Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
Serial connectivity 
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Green mode 
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Disconnected battery notification 
Warns when a battery is not available to provide backup power.
Adjustable voltage sensitivity 
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points 
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms 
Provides notification of changing utility power and UPS power conditions
Automatic self-test 
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery-protected and surge-only outlets 
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Cold-start capable 
Provides temporary battery power when the utility power is out.
Dataline surge protection 
Provides protection of connected equipment from power surges on the data lines.
Hot-swappable batteries 
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Battery failure notification 
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Safety-agency approved 
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Serial connectivity 
Provides management of the UPS via a serial port.
Transformer-block spaced outlets 
Protect equipment with input transformer blocks without blocking access to other receptacles.
USB connectivity 
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries 
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Power-saving outlets 
Automatically cuts power to idle equipment to conserve electricity.
Boost and Trim Automatic Voltage Regulation (AVR) 
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Intelligent battery management 
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Back-UPS Pro Features & Benefits

Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Availability
Energy Management Function
Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Cold-start capable
Provides temporary battery power when the utility power is out.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Manageability
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.












































TECH SPECS

Output

Output Power Capacity
720 Watts / 1200 VA
Max Configurable Power
720 Watts / 1200 VA
Nominal Output Voltage
230V
Efficiency at Full Load
89.0%
Output Frequency (sync to mains)
50 Hz, 60 Hz
Crest Factor
3 : 1
Topology
Line Interactive
Waveform Type
Stepped approximation to a sinewave
Output Connections
(5) IEC 320 C13 (Battery Backup)IEC 320 C13
(5) IEC 320 C13 (Surge Protection)IEC 320 C13
(2) IEC Jumpers (Battery Backup)
Efficiency at Half Load
85.0%

Input

Nominal Input Voltage
230V
Input Frequency
50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
IEC-320 C14
Input voltage range for main operations
176 - 294V
Input voltage adjustable range for mains operation
156 - 300V
Input Breaker Capacity
10  A

Batteries & Runtime

Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
8 hour(s)
Replacement Battery
RBC™ Quantity
1
Runtime Graph
Hover over the line on the graph above to view the runtime at any desired load
This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several variables including battery age, battery charge level, environmental conditions and characteristics of the connected load.

Communications & Management

Interface Port(s)
Optional Simple Signalling RS232 cable, USB
Control panel
Multi-function LCD status and control console
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating
441 Joules
Filtering
Full time multi-pole noise filtering :10% of IEEE surge let-thgouh : zero clamping response time: instantaneous
Data Line Protection
Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)

Physical

Maximum Height
301.00 mm
Maximum Width
112.00 mm
Maximum Depth
380.00 mm
Net Weight
11.60 KG
Shipping Weight
13.20 KG
Shipping Height
387.00 mm
Shipping Width
238.00 mm
Shipping Depth
488.00 mm
Master Carton Units
1.00
Color
Black
SCC Codes
1073130426875 5
Units per Pallet
24.00

Environmental

Operating Environment
0 - 40 °C
Operating Relative Humidity
0 - 95%
Operating Elevation
0-9000 meters
Storage Temperature
-15 - 45 °C
Storage Relative Humidity
0 - 95%
Storage Elevation
0-15000 meters
Audible noise at 1 meter from surface of unit
45.00 dBA

Conformance